Trenchless

Comprehensive Excavation and Underground Utility Services

At Musson Brothers, we specialize in Cured-in-Place Pipe (CIPP) lining, a highly effective trenchless rehabilitation method designed to restore aging or damaged pipes without the need for disruptive excavation. Our CIPP technology provides a durable, long-lasting solution for repairing municipal, residential, or commercial pipes.

trenchless rehabilitation

Key Features of Our CIPP Lining Services:

  1. Trenchless: No digging or disruption to your property.
  2. Cost-Effective: Avoid costly excavation and landscape restoration.
  3. Long-Lasting: All products have a 50-year design life.
  4. Our expert team uses advanced materials and techniques to insert a resin-saturated liner into the existing pipe, which is then cured to form a new, seamless pipe inside the old one. This solution provides a smooth, watertight barrier that prevents leaks, cracks, and further deterioration.
  5. Solution for root intrusion, corrosion, structural damage, or inflow & infiltration to restore lateral to full functionality.
  6. All lining products meet ASTM standards.

Main to Connection Lateral Liner (LMK T-liner)

  • Sealing of the lateral and mainline interface

  • Lining to dictated length up lateral

  • Seal lateral and mainline with hydrophilic gaskets

  • Meets ASTM F2561-20 (one piece gasketed liner) and ASTM F1216 standards

CIPP Lateral Lining (HammerHead Bluelight)

  • Lining from interior/exterior cleanout to directed distance.

  • Capable of lining through transitions and diameters of 4”-12” pipe.

Hydro-excavated cleanout (LMK VAC-A-TEE)

  • 2’x2’ borehole for minimally invasive installation

  • Manufactured to specific outside diameter and materials of the majority of pipes

  • TEE cleanout for access both upstream and downstream

  • Fiberglass sectional for both structural and infiltration prevention

  • Fiberglass allows for stronger design calculations at thinner thicknesses

  • Available in 2’ to 8’ install options from 6”-48” mainlines

UV Mainline CIPP

  • Fiberglass reinforced liner allows design calcs to exceed ASTM standards

  • UV cure allows for a verified controllable cured

  • Hydrophilic gaskets placed at terminating ends of liner to allow for sealed system

  • Resin is fully encapsulated in the liner and is styrene free

  • Capable of installing in 6”-66” diameter mainlines

Sewer Lateral Cleaning and Televising

  • NASSCO certified PACP/LACP televising
  • Lateral locating
  • Cleaning options include:
    • Jetting
    • Robotic
    • High speed milling
  • Cleaning removes roots, minerals, and other potential obstructions